Eur J Endocrinol
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1530/eje.0.1500743
European Journal of Endocrinology, Vol 150, Issue 5, 743-747
Copyright © 2004 by European Society of Endocrinology
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prosst, R.
Right arrow Articles by Gahlen, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prosst, R.
Right arrow Articles by Gahlen, J

Articles

Kinetics of intraoperative fluorescence diagnosis of parathyroid glands

RL Prosst, L Schroeter, and J Gahlen

Department of Surgery, University Hospital Mannheim, Ruprecht-Karls University of Heidelberg, Germany. ruediger@prosst.de

OBJECTIVE: Identification of parathyroid glands is often a challenge even for experienced surgeons. The feasibility and efficacy of fluorescence diagnosis for localization of parathyroids has already been proven in an experimental setting. In preparation for a clinical application of this technique in patients undergoing surgery for hyperparathyroidism, we evaluated the kinetics of fluorescence diagnosis. DESIGN AND METHODS: Fifty rats were randomized into eight groups with different photosensitization parameters using the photosensitizer aminolevulinic acid (ALA): a peritoneal lavage was performed with either 1.5 or 3.0% ALA solution and the induced photosensitization times varied from 0.5, 1 and 2 to 4 h. Under special fluorescence illumination, D-light, the exposed operative site with thyroid, parathyroid glands and neck muscles was examined. The identified parathyroid glands were studied according to fluorescence intensity by spectrometric measurement and compared with surrounding tissue. RESULTS: Photosensitizer accumulation in parathyroid glands, indirectly measured by spectrometry, was up to 3.2 times higher than in thyroid and 2.6 times higher than in muscle tissue (2 h photosensitization with 3.0% ALA). Using 1.5% ALA, the optimum fluorescence intensity and ratio/contrast was slightly lower (parathyroid-to-thyroid ratio x 3.0, parathyroid-to-muscle ratio x 1.9) but was reached earlier (1 h) and hence considered as the parameter of choice for a clinical application. CONCLUSIONS: In future clinical application, intraoperative fluorescence diagnosis is expected to increase the ease of identification of atypically located or supernumeric glands. In combination with preoperative diagnostics, this may result in reduced operation time and avoidance of persistent hypercalcaemia.